By Equipment · HPLC / LC-MS

HPLC / LC-MS Reference Standards & Sample Preparation

Support accurate liquid-chromatography analysis with application-specific reference standards, extraction procedures, filtration, internal standards and matrix-aware quality control.

Sample Matrix

Typical Sample Types for HPLC / LC-MS

The appropriate analytical method depends on the sample matrix, target analytes, concentration range and required accuracy.

Pharmaceutical

Assay, impurities, related substances and raw-material applications.

APIImpurityAssayRaw Material

Food & Beverage

Additives, contaminants, vitamins, sweeteners and other non-volatile compounds.

FoodBeverageAdditiveVitamin

Pesticides & Residues

Multi-residue analysis in food, water and environmental matrices.

PesticideResidueFoodWater

Environmental

Polar and thermally labile compounds not suited to GC-based techniques.

WaterPFASContaminantEnvironmental

Clinical / Biological

Target analytes in biological matrices using validated LC-MS workflows.

PlasmaSerumUrineBiological

Industrial & Chemical

Purity, additives and targeted chemical analysis in industrial samples.

ChemicalAdditivePurityQC
Sample Preparation

Prepare the Sample for Reliable Measurement

HPLC and LC-MS sample preparation is designed to extract target analytes, reduce matrix effects and produce a clean solution compatible with the chromatographic method and detector.

Representative Sample Matrix Control Contamination Control Repeatability
01

Extract / Dissolve

Use an appropriate solvent system, extraction method or digestion route for the target analytes.

02

Clean the Matrix

Use filtration, SPE, QuEChERS, precipitation or other cleanup where required.

03

Adjust Concentration

Dilute or concentrate the extract so it falls within the validated calibration range.

04

Add Internal Standards

For LC-MS, use appropriate internal standards where the method requires compensation for matrix effects and recovery.

CRM Selection

How to Select the Right Reference Material

Reference material selection should follow the real sample matrix, analytes, working range and intended use of the material.

01

Match the Chemical Identity

Use reference standards for the exact compound, impurity or analyte specified by the method.

02

Check Purity & Traceability

Confirm certified purity, uncertainty and documentation appropriate to the application.

03

Match the Calibration Range

Prepare calibration levels that represent routine sample concentrations.

04

Control Matrix Effects

Use matrix-matched QC materials or internal standards when ion suppression or enhancement is important.

Standards & Manufacturers

Reference Material Options

Availability depends on analyte, matrix, concentration range, certification scope and manufacturer portfolio.

Common Standard Types

  • Pharmaceutical reference standards
  • Impurity standards
  • Pesticide and residue standards
  • Food contaminant standards
  • LC-MS internal standards
  • Matrix-matched QC materials

Relevant Manufacturers

Final selection should be based on the exact method, matrix, analyte range and certificate requirements of your laboratory.

Applications

Where HPLC / LC-MS Is Commonly Used

Use the application context to define sample preparation, calibration strategy, CRM type and quality-control plan.

Pharmaceutical QC

Assay, impurity and raw-material analytical methods.

APIImpurityQC

Food Safety

Pesticides, contaminants, additives and residue testing.

FoodResidueSafety

Environmental

Target analysis of polar and emerging contaminants.

WaterPFASContaminant

Research & Method Development

Calibration and method optimization across diverse LC applications.

R&DMethodValidation

Need Help Selecting the Right CRM for HPLC / LC-MS?

Tell us your instrument, sample matrix, target analytes, concentration range and analytical objective. Alpha Prime Lab will help evaluate the appropriate reference material, sample preparation route and calibration approach.